Lutron MG-3002: AC/DC Magnetic Meter
$ 118.8
- Description
- Size Guide
Description
Features:* Wide range, general purpose magnetic measurement. For industrial, mechanical, material, electrical, laboratory field usage.
* Unit : G ( Gauss ), mT ( milli Tesla ).
* DC and AC magnetic field measurement
* DC Range : 300.00 mT/3000.0 mT. AC Range : 150.00 mT/1500.0 mT.
* Resolution : 0.01/0.1 mT, 0.1/1 G.
* N pole/S pole indicator.
* Use Hall sensor with automatic Temp. compensation.
* Zero button for DC magnetic function.
* Separate probe, easy operation and convenient for remote measurement.
* Data hold function for freezing the desired value on display.
* Records Maximum and Minimum readings with Recall.
* RS232/USB computer interface.
* Microprocessor circuit assures maximum possible accuracy, provides special functions and features.
* Heavy duty & compact housing with hard carrying case, designed for easy carry out & operation.
* Auto shut off is available to save battery life.
* Power supply from batteries or DC 9V adapter in.
Specifications:
Circuit: Custom one-chip of microprocessor LSI circuit.
Display: LCD size : 52 mm x 38 mm dual function LCD display.
Measurement Unit: mT(milli Tesla), G (Gauss)
Measurement Range DC:
* mT Range 1( 300.00 mT x 0.01 mT)
* mT Range 2 (3,000.0 mT x 0.1 mT)
* G Range 1( 3,000.0 G x 0.1 G)
* G Range 2(30,000 G x 1 G)
Measurement Range AC:
* mT Range 1( 150.00 mT x 0.01 mT)
* mT Range 2 (1,500.0 mT x 0.1 mT)
* G Range 1(1,500.0 G x 0.1 G)
* G Range 2(15,000 G x 1 G)
Sensor: Hall senor
Accuracy:
* DC ± ( 5 % rdg. + 10 digit )
* AC ± ( 5 % rdg. + 10 digit )
Frequency Response: AC measurement : 50 Hz / 60 Hz
Temp. Compensation for hall sensor: Probe head build the Temp. sensor for useing the ATC ( automatical Temp. compensatioon ).
Field Direction: Uniaxial
Data Hold: Freeze the display reading.
Memory Recall: Maximum & Minimum value.
Display Sampling Time: Approx. 1 second.
Power Off: Manual off by push button or Auto shut off to save battery life.
Data Output: RS 232/USB PC serial interface.
* Connect the optional RS232 cable UPCB-02 will get the RS232 plug.
* Connect the optional USB cableUSB-01 will get the USB plug.
Operating Temperature: 0 to 50 ℃.
Operating Humidity: Less than 85% R.H.
Power Supply: DC 1.5 V battery ( UM4, AAA ) x 6 PCs, Alkaline/heavy duty type or equivalent.
Power Current: Approx. DC 20.5 mA .
Weight: Approx. 270 g/0.60 LB.
( include battery & probe )
Dimension:
Main instrument: 200 x 68 x 30 mm ( 7.9 x 2.7 x 1.2 inch ).
Probe: 198 x 25 x 19 mm ( 7.8 x 1.0 x 0.7 inch ).
Accessories Included: Instruction manual (1 PC), Magnetic Probe (1 PC), Hard Carrying case, CA-06 (1 PC)
Optional Accessories: RS232 cable, UPCB-02, USB cable, USB-01, Data Acquisition software, SW-U801-WIN