-40%
0-1.5T 0,5% 43205 Teslameter, Gaussmeter, Magnetometer an-g Alpha Lab, F.W. Bell
$ 792
- Description
- Size Guide
Description
43205 Multifunctional Digital Exact Micro Teslameter, Gaussmeter, Magnetometer analog of Alpha Lab, F.W. Bell,but has the same or better characteristics:
Measured Value:
Measurement range
C
onstant magnetic field
Induct
ance
R
adial component
0 - 19,99
mT
0 - 199,9
mT
0 - 1500
mT
A
xial
component
0 - 19,99
mT
R
adial
component of RMS value of
inductance alternating magnetic field
0 - 199
mkT
0 - 1,99
mkT
0 - 19,9
mkT
0 - 100
mkT
Accuracy class:
0,5% - 4%;
(0-1500mT, ±0,5%), (0-19,99мТл, ±2,5%) ,
(0-100mT, ±4%)
.
Nomainal
frequency
:
45-50Hz;
Operating
frequency range:
45 - 1000 Hz;
Frequency:
50
±0,5 Hz;
Alternating Voltage:
220V
±4,4V;
The average service at least
10 years;
MTBF
6,000 hours;
Dimmensions:
380х317х133mm;
Weight:
8 kg.
Warranty 12 Months
Universal
digital
teslameter
43205
Designed
to measure
:
-
radial
component of
constant magnetic field induction
(0-
1500mT, ± 0.5%)
-
radial
component of sinusoidal RMS form
of
alternating magnetic field
(0-
100mT, ±
4%);
-
axial component of
constant field induction
(
0-19.99
mT
, ± 2.5%)).
Universal
Teslameter
43205
(hereinafter
the device
)
is used for
measurements:
radial
component of sinusoidal RMS form
of
alternating magnetic field with the help of primary converter
thickness do not exceed
0.95 mm
;
axial component of
constant field induction
with the help of
6
mm diameter primary converter.
Connecting
primary transducers
with input
devices connector
of
Teslameter
43205
is carried out
with
flexible cables
length 1.5
m.
Selecting measurement range and type of measured induction - manual. Polarity of static magnetic field induction determination, and its indication by device
Teslameter 43205
- automatic.
Climatic factors values in accordance with GOST 22261-82, group 2 and GOST 15150-69, conditions YXL 4.2. DC and AC magnetic fields radial component induction measured by primary measuring converter PIP-PAD, made in the probe form. Axial induction component of static magnetic field is measured by primary measuring transducer PIP-AKC, made in the probe form.
Warning! Mechanical force application to measuring parts of primary transducers is unacceptable!
Teslameters 43205
operating conditions are shown in Table 1.
Teslametrs 43205
Table 1
Influence value
Influencing quantities value
Ambient temperature, ° C
10-35
Relative humidity at 25, ° C,%
80
Atmosphere pressure, kPa (mm Hg)
84 – 106.7 (630-800)
Voltage supply, V
198 - 242
Frequency, Hz
49.5 – 50.5
Curve form measured by induction of alternating magnetic field
sinusoidal with
harmonics coefficient
up to 5 %
Technical characteristics
Measurement ranges and their corresponding limits of basic acceptable error values in normal using conditions are shown in Table 2.
Table 2
Type of
measuring value
Measurement range,
mT
Acceptable
basic error limit
,%
Constant magnetic field Induction
Radial component
0 - 19.99mT
±[0.5+0.5(|
Bk / Bx
|-1)]
0 - 199.9mT
0 - 1500mT
Axial
component
0 - 19.99mT
±[2.5+2.5(|
Bk / Bx
|-1)]
Radial
component RMS value of
alternating magnetic field
induction
0-199mkT
±[6+6(|
Bk / Bx
|-1)]
0 - 1.99mT
±[4+4(|
Bk / Bx
|-1)]
0 - 19.9mT
0 - 100mT
Bk
-
final value of
specified measurement range;
Bx
- measured value.
Frequency ranges
of alternating magnetic field
measured
induction are shown
in Table 3.
Table 3
Final value of
measuring range
Normal
frequency range
, Hz
Working
frequency range
,
Hz
199mkT
45 - 55
45 - 1000
1.99mT; 19.9mT; 100mT
45 - 55
-
Normal
working
conditions are shown in
Table 4.
Table 4
Influence value
Normal value
(normal
value
range
)
Ambient temperature
, ° C
20±5
Relative humidity, %
30-80
Atmospherepressure
, kPa
(mm
Hg)
84-106.7(630-800)
Frequency
, Hz
50±0.5
Frequency of
measured
magnetic field
, Hz
45-55
Alternating current voltage supply, V
220±4.4
Curve form of AC
power supply
Sinusoidal with
harmonics
coefficient
up to
5 %
External constant magnetic field
Earth magnetic field
Curve form of alternating magnetic field of measured
induction
Sinusoidal with
harmonics
coefficient
up to
2 %
Teslameters
43205 additional acceptable
error limit
,
caused by ambient temperature changes
from normal to
maximum working temperatures values
,
equal to acceptable
basic error limit
for every 10
° C
of
temperature changes.
Acceptable
additional error
limit caused by changes in
alternating magnetic field
induction frequency from normal to
any value
within frequencies
working
range (table
3), is
equal to acceptable
basic error limit
.
Acceptable
additional error limit caused by harmonics
coefficient
changes of measured signal
from normal
value
to value not more than 5
%,
is
equal to acceptable
basic error limit.
Acceptable
additional error
limit caused by voltage
supply
changes from normal
to any
value within
working range
, is
equal to acceptable
basic error limit.
Teslameters
43205 digital
reading device
indicates
:
constant magnetic field
measuring
induction
result
of
3.5
- bit
digital
reading device
;
Alternating magnetic field
measuring
induction
result
of 2.5
-bit
digital
reading device
;
decimal point position
;
"-" sign
in
negative polarity
of constant magnetic
field measuring
induction
, in
positive polarity sign
is not indicated
.
Note
.
Magnetic induction measured value
is
accepted
positive if magnetic induction vector
is directed
into measuring
probe
plane
at
marker thread
(for
PIP-
PAD) or
measuring
probe
(for
PIP-
AKC).
In
PIP-
PAD
marking label
indicates
transmitter location Hall
probe.
In PIP-
AKC
converter
Hall
is located
in probe back side.
Operation mode setup time is
less than 30 minutes
.
Teslameters
43205
settling reading
time is
less than
3 seconds. Devices
continuous
operating time is 8 hours
with 1h break
for
re-enable.
Power supply
is not more than
30 VA
.
Devices case
dimensions 380x317x133
mm.
Dimensions
with hand
carrying
380x341x180
mm.
Weight of device
is not
more than 8
kg.
Device
in any measuring
ranges
stands
for
1 min.
overload
, whose value
does not exceed
final
value subsequent
measurement range
, but
not more than 120
% from final value
of max measurement
ranges.
Teslametr
43205
are
restored
,
single-function
.
Mean time between failures is
at least
3000 hours
, set-failure
operating time is
at least 300
hours.
Failure criteria
:
basic error
output
out of acceptable limits
.
Average time
restoring
efficient condition
is not
more than 24 hours. Full
average lifetime is
not less than 8
years.
Specified service life is at least 4
years.
Criteria for
limiting condition
:
technical and
economic
inadvisability of
manufacturing
repair (
restoration),
if
direct
repair costs
exceed price of device.
Device
contains following
quantity of precious
metals:
Gold
-
0.466
g;
Silver
-
3.625
g.
Warranty 12 months.
This device was also used in USSR and Russian army. So it has best quality
,
longevity, and permanence characteristic.
Condition:
NEW (not used, but from an old stock). Tested and 100% workable.
If necessary, the device can be calibrated and provided with the calibration certificate
from Government Standardization Institute ( +145-265usd).
Also we can provide other resistance, capacitance and inductance standards, decade box and other etalons.
Please take a look on my other items!
If you haven’t found the needed item in my listing, please contact me. I’ll try to help you.
Technical characteristics:
43205 is designed for:
-
R
adial component of
the induction
of a constant magnetic
field and the
RMS
sinusoidal
alternating magnetic
field by means of
the primary converter
(
thickness
0.95 mm)
;
- Axial
component of the
induction of
constant magnetic field
with the
primary head (
diameter 6
mm).
Temperature
10-35 ° C;
Relative humidity
25 to 80%;
Atm. pressure
84-106,7 kPa (630-800 mmHg).
This device can be also marked as:
43205
,
43-205
,
43 205
,
4-3-2-0-5,
4 3 2 0 5
,
Micro Teslameter, Gaussmeter, Magnetometer
.
Photos
If necessary we can take photos of a device from various angles.
Technical Documentation
In case you didn't find in technical specifications for the device all necessary information you are interested in, feel free to contact me. I will look through the technical documentation for the device and I will be happy to consult you.
Also I may speak directly with the manufacturer and find out more specific information about this product.
If some technical parameters for the device (error, accuracy, measuring range, operating voltage and frequency) do not meet your requirements, please, e-mail me and I will negotiate with the manufacturer whether it is possible to deliver you a device on the desired specifications without a cost increase and in the shortest time.
On delivering the device, electric circuit diagrams and all technical documentation for operation, calibration and maintenance will be supplied. Also there will be documents that testify the accuracy and compliance with specifications.
In addition, translation of technical documentation into the customer’s language may be discussed.
Delivery set
On delivering the device will be completely ready for use.
There are all necessary cables, adapters, sensors and spare parts as envisaged in technical documentation. Hence, there is no point in purchasing any additional repair & measurement equipment.
Warranty
Warranty of this item
- 12 month.
Before sending a device, all devices are checked whether they comply with all technical specifications.
Highly qualified metrology engineers carry out the check-up of every instrument at a specialized laboratory and with the help of master gages.
If necessary, we can send you photos or video with the check-up process.
I ship only fully working devices complying with all parameters.
The warranty for this device is 1 year from the date of shipment from my warehouse.
Within 1 year term I will provide the repair of the device for free in case of manufacturing defect or when the technical parameters do not comply with technical documentation. You will have to pay only for delivery.
When a device is out of order due to your fault (its fall, it is flooded with water, the power supply does not meet the specified technical requirements, input signals exceed the norm, etc.) or there are conspicuous marks of casing opening (broken warranty labels), it is considered a non-warranty repair.
Within 1 year term we can advise you for free on the device operation.
After-warranty service
After warranty termination I can arrange a paid repair and technical maintenance of a device as well as I can sell you all necessary spare parts for repair at minimum prices. I always have them in stock.
Packaging
Immediately after checking, the device will be wrapped in several layers of strong air-bubble film and placed into a strong cardboard box. Extra cardboard plates will be used for fixation.
If necessary, wooden box or pallet may be used. For a more reliable fixation foam can be applied. The whole box will be placed in a waterproof polyethylene bag which will be wound with several layers of packing tape.
A special handle will be made for ease of transportation.
Thus, I guarantee qualitative and conscientious packing of the device that reduces to minimum the possibility of damage during transportation.
Discount (from-10% to -90%)
I suggest you a device which is unique in its class and price category with the following specifications: (accuracy, measurement range, error, temperature operating conditions), endurance and durability (military performance, aluminum, stainless steel, titanium or carbolite casing, shock and vibration resistance, high maintainability and reliability), free measuring kit (cables, adapters, load, fuses, etc.), 1year warranty.
Unused cheap devices with the same specifications, accuracy and durability do not exist.
If you consider the price for this device unreasonably high, and you know the similar equipment at a lower price, please, let me know.
I will help you to compare these two models. In case your model (which is cheaper) is the same as the device I suggest or even it is better, then
I guarantee to sell you a unit at that cheaper price with additional 10% discount.
Shipping details:
Please, mind that I ship from Ukraine (Europe, +2), so that the shipping time may differ from your local time.
I send goods via AirMailpost.
App. delivery time :
Europe – 7-15 days;
USA, Japan&others – 10-20 days (depends on a country).
I will ship in 10-15 business days after payment clearance.
The goods may also be delivered by the express mail services such as DHL, UPS, FedEx, TNT or EMS.
With express delivery you will mostly receive your goods within 3-7 working days.
Payment details:
I expect payment in 4 days after the auction ends.
I accept a PayPal payment as the safest way of payment (preferably).
If you do not have a PayPal account you can pay by wire transfer to my credit card.
Other variants of payment are acceptable, for example in case of pickup way of shipping, i can accept cash payment.
(This will be an official purchase on eBay).
Please, tell me if you cannot pay in time, we can always negotiate it.
When purchasing a few items, you’ll save on shipping.
Return policy:
I accept refunds and returns. If there is something wrong with the device, please, inform me within 5 days after receiving it.
I will refund your costs or send you the other item, as you wish (
after I receive the previous item
).
Please only serious bidders!