-40%

0-1.5T 0,5% 43205 Teslameter, Gaussmeter, Magnetometer an-g Alpha Lab, F.W. Bell

$ 792

Availability: 100 in stock
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Item must be returned within: 30 Days
  • MPN: Does Not Apply
  • Brand: 43205
  • All returns accepted: Returns Accepted
  • Restocking Fee: No
  • Return shipping will be paid by: Buyer
  • Condition: New

    Description

    43205 Multifunctional Digital Exact Micro Teslameter, Gaussmeter, Magnetometer analog of Alpha Lab, F.W. Bell,
    but has the same or better characteristics:
    Measured Value:
    Measurement range
    C
    onstant magnetic field
    Induct
    ance
    R
    adial component
    0 - 19,99
    mT
    0 - 199,9
    mT
    0 - 1500
    mT
    A
    xial
    component
    0 - 19,99
    mT
    R
    adial
    component of RMS value of
    inductance alternating magnetic field
    0 - 199
    mkT
    0 - 1,99
    mkT
    0 - 19,9
    mkT
    0 - 100
    mkT
    Accuracy class:
    0,5% - 4%;
    (0-1500mT, ±0,5%),  (0-19,99мТл, ±2,5%) ,
    (0-100mT, ±4%)
    .
    Nomainal
    frequency
    :
    45-50Hz;
    Operating
    frequency range:
    45 - 1000 Hz;
    Frequency:
    50
    ±0,5 Hz;
    Alternating Voltage:
    220V
    ±4,4V;
    The average service at least
    10 years;
    MTBF
    6,000 hours;
    Dimmensions:
    380х317х133mm;
    Weight:
    8 kg.
    Warranty 12 Months
    Universal
    digital
    teslameter
    43205
    Designed
    to measure
    :
    -
    radial
    component of
    constant magnetic field induction
    (0-
    1500mT, ± 0.5%)
    -
    radial
    component of sinusoidal RMS form
    of
    alternating magnetic field
    (0-
    100mT, ±
    4%);
    -
    axial component of
    constant field induction
    (
    0-19.99
    mT
    , ± 2.5%)).
    Universal
    Teslameter
    43205
    (hereinafter
    the device
    )
    is used for
    measurements:
    radial
    component of sinusoidal RMS form
    of
    alternating magnetic field with the help of primary converter
    thickness do not exceed
    0.95 mm
    ;
    axial component of
    constant field induction
    with the help of
    6
    mm diameter primary converter.
    Connecting
    primary transducers
    with input
    devices connector
    of
    Teslameter
    43205
    is carried out
    with
    flexible cables
    length 1.5
    m.
    Selecting measurement range and type of measured induction - manual. Polarity of static magnetic field induction determination, and its indication by device
    Teslameter 43205
    - automatic.
    Climatic factors values in accordance with GOST 22261-82, group 2 and GOST 15150-69, conditions YXL 4.2. DC and AC magnetic fields radial component induction measured by primary measuring converter PIP-PAD, made ​​in the probe form. Axial induction component of static magnetic field is measured by primary measuring transducer PIP-AKC, made in the probe form.
    Warning! Mechanical force application to measuring parts of primary transducers is unacceptable!
    Teslameters 43205
    operating conditions are shown in Table 1.
    Teslametrs 43205
    Table 1
    Influence value
    Influencing quantities value
    Ambient temperature, ° C
    10-35
    Relative humidity at 25, ° C,%
    80
    Atmosphere pressure, kPa (mm Hg)
    84 – 106.7 (630-800)
    Voltage supply, V
    198 - 242
    Frequency, Hz
    49.5 – 50.5
    Curve form measured by induction of alternating magnetic field
    sinusoidal with
    harmonics coefficient
    up to 5 %
    Technical characteristics
    Measurement ranges and their corresponding limits of  basic acceptable error values ​​ in normal using conditions are shown in Table 2.
    Table 2
    Type of
    measuring value
    Measurement range,
    mT
    Acceptable
    basic error limit
    ,%
    Constant magnetic field Induction
    Radial component
    0 - 19.99mT
    ±[0.5+0.5(|
    Bk / Bx
    |-1)]
    0 - 199.9mT
    0 - 1500mT
    Axial
    component
    0 - 19.99mT
    ±[2.5+2.5(|
    Bk / Bx
    |-1)]
    Radial
    component RMS value of
    alternating magnetic field
    induction
    0-199mkT
    ±[6+6(|
    Bk / Bx
    |-1)]
    0 - 1.99mT
    ±[4+4(|
    Bk / Bx
    |-1)]
    0 - 19.9mT
    0 - 100mT
    Bk
    -
    final value of
    specified measurement range;
    Bx
    - measured value.
    Frequency ranges
    of alternating magnetic field
    measured
    induction are shown
    in Table 3.
    Table 3
    Final value of
    measuring range
    Normal
    frequency range
    , Hz
    Working
    frequency range
    ,
    Hz
    199mkT
    45 - 55
    45 - 1000
    1.99mT; 19.9mT; 100mT
    45 - 55
    -
    Normal
    working
    conditions are shown in
    Table 4.
    Table 4
    Influence value
    Normal value
    (normal
    value
    range
    )
    Ambient temperature
    , ° C
    20±5
    Relative humidity, %
    30-80
    Atmospherepressure
    , kPa
    (mm
    Hg)
    84-106.7(630-800)
    Frequency
    , Hz
    50±0.5
    Frequency of
    measured
    magnetic field
    , Hz
    45-55
    Alternating current voltage supply, V
    220±4.4
    Curve form of AC
    power supply
    Sinusoidal with
    harmonics
    coefficient
    up to
    5 %
    External constant magnetic field
    Earth magnetic field
    Curve form of alternating magnetic field of measured
    induction
    Sinusoidal with
    harmonics
    coefficient
    up to
    2 %
    Teslameters
    43205 additional acceptable
    error limit
    ,
    caused by ambient temperature changes
    from normal to
    maximum working temperatures values​
    ,
    equal to acceptable
    basic error limit
    for every 10
    ° C
    of
    temperature changes.
    Acceptable
    additional error
    limit caused by changes in
    alternating magnetic field
    induction frequency from normal to
    any value
    within frequencies
    working
    range (table
    3), is
    equal to acceptable
    basic error limit
    .
    Acceptable
    additional error limit caused by harmonics
    coefficient
    changes of measured signal
    from normal
    value
    to value not more than 5
    %,
    is
    equal to acceptable
    basic error limit.
    Acceptable
    additional error
    limit caused by voltage
    supply
    changes from normal
    to any
    value within
    working range
    , is
    equal to acceptable
    basic error limit.
    Teslameters
    43205 digital
    reading device
    indicates
    :
    constant magnetic field
    measuring
    induction
    result
    of
    3.5
    - bit
    digital
    reading device
    ;
    Alternating magnetic field
    measuring
    induction
    result
    of 2.5
    -bit
    digital
    reading device
    ;
    decimal point position
    ;
    "-" sign
    in
    negative polarity
    of constant magnetic
    field measuring
    induction
    , in
    positive polarity sign
    is not indicated
    .
    Note
    .
    Magnetic induction measured value
    is
    accepted
    positive if magnetic induction vector
    is directed
    into measuring
    probe
    plane
    at
    marker thread
    (for
    PIP-
    PAD) or
    measuring
    probe
    (for
    PIP-
    AKC).
    In
    PIP-
    PAD
    marking label
    indicates
    transmitter location Hall
    probe.
    In PIP-
    AKC
    converter
    Hall
    is located
    in probe back side.
    Operation mode setup time is
    less than 30 minutes
    .
    Teslameters
    43205
    settling reading
    time is
    less than
    3 seconds. Devices
    continuous
    operating time is 8 hours
    with 1h break
    for
    re-enable.
    Power supply
    is not more than
    30 VA
    .
    Devices case
    dimensions 380x317x133
    mm.
    Dimensions
    with hand
    carrying
    380x341x180
    mm.
    Weight of device
    is not
    more than 8
    kg.
    Device
    in any measuring
    ranges
    stands
    for
    1 min.
    overload
    , whose value
    does not exceed
    final
    value subsequent
    measurement range
    , but
    not more than 120
    % from final value
    of max measurement
    ranges.
    Teslametr
    43205
    are
    restored
    ,
    single-function
    .
    Mean time between failures is
    at least
    3000 hours
    , set-failure
    operating time is
    at least 300
    hours.
    Failure criteria
    :
    basic error
    output
    out of acceptable limits
    .
    Average time
    restoring
    efficient condition
    is not
    more than 24 hours. Full
    average lifetime is
    not less than 8
    years.
    Specified service life is at least 4
    years.
    Criteria for
    limiting condition
    :
    technical and
    economic
    inadvisability of
    manufacturing
    repair (
    restoration),
    if
    direct
    repair costs
    exceed price of device.
    Device
    contains following
    quantity of precious
    metals:
    Gold
    -
    0.466
    g;
    Silver
    -
    3.625
    g.
    Warranty 12 months.
    This device was also used in USSR and Russian army. So it has best quality
    ,
    longevity, and permanence characteristic.
    Condition:
    NEW (not used, but from an old stock). Tested and 100% workable.
    If necessary, the device can be calibrated and provided with the calibration certificate
    from Government Standardization Institute ( +145-265usd).
    Also we can provide other resistance, capacitance and inductance standards, decade box and other etalons.
    Please take a look on my other items!
    If you haven’t found the needed item in my listing, please contact me. I’ll try to help you.
    Technical characteristics:
    43205 is designed for:
    -
    R
    adial component of
    the induction
    of a constant magnetic
    field and the
    RMS
    sinusoidal
    alternating magnetic
    field by means of
    the primary converter
    (
    thickness
    0.95 mm)
    ;
    - Axial
    component of the
    induction of
    constant magnetic field
    with the
    primary head (
    diameter 6
    mm).
    Temperature
    10-35 ° C;
    Relative humidity
    25 to 80%;
    Atm. pressure
    84-106,7 kPa (630-800 mmHg).
    This device can be also marked as:
    43205
    ,
    43-205
    ,
    43 205
    ,
    4-3-2-0-5,
    4 3 2 0 5
    ,
    Micro Teslameter, Gaussmeter, Magnetometer
    .
    Photos
    If necessary we can take photos of a device from various angles.
    Technical Documentation
    In case you didn't find in technical specifications for the device all necessary information you are interested in, feel free to contact me.  I will look through the technical documentation for the device and I will be happy to consult you.
    Also I may speak directly with the manufacturer and find out more specific information about this product.
    If some technical parameters for the device (error, accuracy, measuring range, operating voltage and frequency) do not meet your requirements, please, e-mail me and I will negotiate with the manufacturer whether it is possible to deliver you a device on the desired specifications without a cost increase and in the shortest time.
    On delivering the device, electric circuit diagrams and all technical documentation for operation, calibration and maintenance will be supplied. Also there will be documents that testify the accuracy and compliance with specifications.
    In addition, translation of technical documentation into the customer’s language may be discussed.
    Delivery set
    On delivering the device will be completely ready for use.
    There are all necessary cables, adapters, sensors and spare parts as envisaged in technical documentation. Hence, there is no point in purchasing any additional repair & measurement equipment.
    Warranty
    Warranty of this item
    - 12  month.
    Before sending a device, all devices are checked whether they comply with all technical specifications.
    Highly qualified metrology engineers carry out the check-up of every instrument at a specialized laboratory and with the help of master gages.
    If necessary, we can send you photos or video with the check-up process.
    I ship only fully working devices complying with all parameters.
    The warranty for this device is 1 year from the date of shipment from my warehouse.
    Within 1 year term I will provide the repair of the device for free in case of manufacturing defect or when the technical parameters do not comply with technical documentation. You will have to pay only for delivery.
    When a device is out of order due to your fault (its fall, it is flooded with water, the power supply does not meet the specified technical requirements, input signals exceed the norm, etc.) or there are conspicuous marks of casing opening (broken warranty labels), it is considered a non-warranty repair.
    Within 1 year term we can advise you for free on the device operation.
    After-warranty service
    After warranty termination I can arrange a paid repair and technical maintenance of a device as well as I can sell you all necessary spare parts for repair at minimum prices. I always have them in stock.
    Packaging
    Immediately after checking, the device will be wrapped in several layers of strong air-bubble film and placed into a strong cardboard box. Extra cardboard plates will be used for fixation.
    If necessary, wooden box or pallet may be used. For a more reliable fixation foam can be applied. The whole box will be placed in a waterproof polyethylene bag which will be wound with several layers of packing tape.
    A special handle will be made for ease of transportation.
    Thus, I guarantee qualitative and conscientious packing of the device that reduces to minimum the possibility of damage during transportation.
    Discount (from-10% to -90%)
    I suggest you a device which is unique in its class and price category with the following specifications: (accuracy, measurement range, error, temperature operating conditions), endurance and durability (military performance, aluminum, stainless steel, titanium or carbolite casing, shock and vibration resistance, high maintainability and reliability), free measuring kit (cables, adapters, load, fuses, etc.), 1year warranty.
    Unused cheap devices with the same specifications, accuracy and durability do not exist.
    If you consider the price for this device unreasonably high, and you know the similar equipment at a lower price, please, let me know.
    I will help you to compare these two models. In case your model (which is cheaper) is the same as the device I suggest or even it is better, then
    I guarantee to sell you a unit at that cheaper price with additional 10% discount.
    Shipping details:
    Please, mind that I ship from Ukraine (Europe, +2), so that the shipping time may differ from your local time.
    I send goods via AirMailpost.
    App. delivery time :
    Europe – 7-15 days;
    USA, Japan&others – 10-20 days (depends on a country).
    I will ship in 10-15 business days after payment clearance.
    The goods may also be delivered by the express mail services such as DHL, UPS, FedEx, TNT or EMS.
    With express delivery you will mostly receive your goods within 3-7 working days.
    Payment details:
    I expect payment in 4 days after the auction ends.
    I accept a PayPal payment as the safest way of payment (preferably).
    If you do not have a PayPal account you can pay by wire transfer to my credit card.
    Other variants of payment are acceptable, for example in case of pickup way of shipping, i can accept cash payment.
    (This will be an official purchase on eBay).
    Please, tell me if you cannot pay in time, we can always negotiate it.
    When purchasing a few items, you’ll save on shipping.
    Return policy:
    I accept refunds and returns. If there is something wrong with the device, please, inform me within 5 days after receiving it.
    I will refund your costs or send you the other item, as you wish (
    after I receive the previous item
    ).
    Please only serious bidders!